Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Water Sci Technol ; 84(1): 55-65, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34280154

RESUMO

In this study, the removal of hexavalent chromium from aqueous solution were examined using activated charcoal derived from Sapindus trifoliate L fruit biomass in continuous fixed-bed column studies. The activated S. trifoliate L fruit charcoal was prepared by treating the fruit powder using concentrated nitric acid solution. Experiments were performed to investigate the effect of bed height and initial concentration on the breakthrough and saturation times. The breakthrough and saturation time increases with increase in bed height and initial concentration of chromium solutions. The maximum adsorption capacity of S. trifoliate L charcoal for hexavalent chromium was found to be 1.719 mg/g in the bed height 15 cm and initial concentration 10 mg/L, respectively. Column data required at various conditions were explained using Bohart-Adams and Thomas model. Two models were found to be suitable to describe the definite part of the dynamic behaviour of the column with regard to bed-height and initial concentration of hexavalent chromium. On comparison of Adjusted R2 and estimated standard error, the Thomas model was found to best-fitted model and can be used to predict the adsorption of the hexavalent chromium in fixed-bed column studies. Activated S. trifoliate L fruit charcoal was characterised by SEM-EDX and FTIR analysis.


Assuntos
Sapindus , Poluentes Químicos da Água , Purificação da Água , Adsorção , Biomassa , Carvão Vegetal , Cromo/análise , Frutas/química , Cinética , Poluentes Químicos da Água/análise
2.
Rep Pract Oncol Radiother ; 26(6): 976-983, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34992871

RESUMO

BACKGROUND: The aim of the study was to assess the dosimetric comparison of bone marrow between standard IMRT(SD-IMRT) and bone marrow sparing IMRT (BMS-IMRT) among carcinoma cervix patients who underwent radical or adjuvant chemoradiation in a tertiary cancer center. MATERIALS AND METHODS: Forty eligible patients of histo-pathologically proven carcinoma cervix were enrolled in the study that was randomized on a 1:1 basis between SD-IMRT and BMS-IMRT from July 2018 to October 2019. The whole pelvis, bilateral femoral heads, and upper 1/3rd femur were contoured using the whole bone technique as a surrogate marker for the bone marrow. In both arms, V10, V20, and V40, bone marrow was noted along with mean, maximum, minimum dose, and total volume. DVH for the bone marrow in both arms was compared using the unpaired student t-test. RESULTS: We found no significant difference in the mean of various parameters in SD-IMRT arm vs. BMS IMRT arm - for the bone marrow: V10 (89 ± 4.3% vs. 86.7 ± 3.7%), V20 (73.2 ± 5.3% vs. 73.1 ± 4.5%), V40 (23.9 ± 5.4% vs. 26.6 ± 7.4%) and, similarly, for mean dose (28.1 ± 3.5% vs. 28.1 ± 1.8%), maximum dose (53.4 ± 0.58% vs. 53.2 ± 0.58%), minimum dose (0.33 ± 0.18% vs. 0.38 ± 0.38%), total volume (961 ± 110 cc vs. 901 ± 152 cc). CONCLUSION: This study shows no statistically significant difference in dosimetry between the two groups, which suggests that SD-IMRT spares the bone marrow adequately. Therefore, the need for BMS-IMRT using the present contouring technique does not give any added advantage over SD-IMRT. However, large sample size, other novel contouring technique, and multivariate analysis are needed to reach a definite conclusion.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...